Customized Cryogenic Piping Systems
Dewar Recommendations
The Bayard Nitro Mixer control requires a Dewar with a maintained pressure of 22 psig and an integrated Pressure Building System. This system features a built-in pressure-building mechanism to support liquid withdrawal. It includes a pressure-building coil, a pressure-building valve, and a pressure-building regulator, all connected in series. The pressure-building regulator ensures a stable vessel pressure during liquid withdrawal, as long as the container has a sufficient liquid level and the pressure-building valve remains open.
Vacuum Jacketed Valve
Flow plugs must be installed in the vacuum-jacketed valve to deliver a 50 mL (40 grams) dose of liquid nitrogen within 2 seconds at a Dewar pressure of 22 psig. A flow plug is a flow control element integrated within a valve, specifically engineered for liquid nitrogen (LN₂) applications to precisely regulate dosing and maintain consistent flow under cryogenic conditions.
If a higher Dewar pressure is used, a pneumatic pressure regulator on the diaphragm control valve is required to compensate for the increased flow. The dose will then need to be recalibrated accordingly.
Rental liquid nitrogen Dewars have been observed operating at pressures above 22 psig.


Custom Solutions
NSF Commercial Series 8 Quart Stand Mixer
Extremely Cold Liquid Nitrogen Do Not Touch
8 Quart Stand Mixer Agitator Shaft Pin
Mixer Pin
The customer reported that the pin is coming loose and falling out.
Pin Location
To perform the repair, follow these steps:
Place the metal pin in the mixer bowl.
Pour liquid nitrogen over the pin until it is fully submerged.
Wait 1–2 minutes for the pin to contract.
Using long-nose pliers, carefully remove the pin and insert it back into the shaft. As it returns to its original size, it will lock securely in place.
Long Nose Pliers
Mixer Walking from LN2 Dispenser
Home Depot
Product Information
Internet # 206758282
Model # 49072
Store SKU # 1001687347
Replace screws with #8-32 x 1/2 in. Stainless Steel Round Head Machine Screw
Use bumpers to keep the mixer in place near the LN2 dispenser.
Adjust screws as needed based on inside location of mixer stand.
When drilling holes, avoid locations of the mixer’s rubber feet.
1 for each direction of movement




Place mixer on top of bumpers
The mixer will remain in place at the dispenser after the bumpers are installed.
Bumpers are hidden under mixer base.
Speed Selector Hard Stop
New Mixer Burn-In
Speed Selector Hard Stop
Video installation



Baseline Calibration
Baseline Calibration Materials Needed:
Small Digital Scale (Maximum Capacity: 5000g / 11 lbs)
On the touchscreen, select Help, then choose Baseline


Baseline Calibration Procedure:


Troubleshooting: Inconsistent Ice Cream Texture
Potential cause
What may be happening
Dairy vs. non-dairy profile
Different freezing characteristics require different process parameters.
Incorrect LN₂ dose
The automatic cycle may deliver insufficient nitrogen.
Variable base temperature
Warmer base requires more energy removal.
Dewar pressure variation
Changes in pressure can affect dosing performance.
Inconsistent formulation
Fat, sugar, solids, and stabilizers affect freezing behavior.
Incorrect cycle termination
The controller may complete its cycle before the desired texture is reached. ICY
Overrun Test Procedure:
Each freezing profile is individually engineered for the specific product type and serving size. Customized profiles account for differences in ingredients, fat content, solids, and batch volume to optimize freezing time, overrun, texture, and consistency. This ensures each product—from dairy ice cream to sorbet—achieves its intended finished quality. One profile cannot deliver the same results across all products and sizes.
Installation
Nitro Mixer Installation







Connecting and Disconnecting 25 liter Dewar Video
Remote Technical Support for Customers Using Cellular Routers
Enables real-time monitoring and management of industrial equipment from any location.
Eliminating the need for on-site visits, saving time and costs.
Remote Monitoring & Control
Troubleshooting: Diagnosing hardware issues.
Setup Assistance: Guiding users through the installation and initial configuration of the Nitro Mixer.
Performance Optimization: Assisting with fine-tuning the Nitro Mixer settings to improve performance and stability.
Custom Recipe Calibration: Helping Add and Manage Custom Recipe Processing.
Software Updates: Ensuring the Nitro Mixer stays up-to-date with the latest software.
Security & Isolation is a key concern when working with nitrogen control. That’s why we do not connect to the internet and instead use a dedicated cellular connection, which is disconnected once the task is complete.
Contact
Please let me know if the system is meeting your expectations.
We always welcome feedback to help us enhance our product and services.
Email: Rick@NitroMixer.com


Bayard Inc.
Hours
Mon 08:00 am – 04:00 pm
Tue 08:00 am – 04:00 pm
Wed 08:00 am – 04:00 pm
Thu 08:00 am – 04:00 pm
Fri 08:00 am – 04:00 pm
Sat Closed
Sun Closed
Talk to an Automation Engineer
Request More Information
Temecula, CA 92591
(909) 239-1004
©Copyright © 2026 Bayard Inc.- All Rights Reserved.